The Citing articles tool gives a list of articles citing the current article. The citing articles come from EDP Sciences database, as well as other publishers participating in CrossRef Cited-by Linking Program . You can set up your personal account to receive an email alert each time this article is cited by a new article (see the menu on the right-hand side of the abstract page).
Cited article:
C. Rapin , A. D’Huysser , J.-P. Labbe , L. Gengembre , P. Steinmetz
Rev. Met. Paris, 93 5 (1996) 719-727
Published online: 2017-01-18
This article has been cited by the following article(s):
14 articles
The influence of bronze composition on the protective properties of phosphonic acid films
Dajana Mikić, Magdalena Osrečak, Matjaž Finšgar, Arijeta Bafti and Helena Otmačić Ćurković Colloids and Surfaces A: Physicochemical and Engineering Aspects 689 133744 (2024) https://doi.org/10.1016/j.colsurfa.2024.133744
Phosphonic Acids as Corrosion Inhibitors and Adhesion Promoters for Organic Coatings and Bronze
Dajana Mikić, Floren Radovanović-Perić and Helena Otmačić Ćurković Materials 17 (15) 3710 (2024) https://doi.org/10.3390/ma17153710
Efficiency and durability of protective treatments on cultural heritage copper corrosion layers
Emilande Apchain, Delphine Neff, Jean-Paul Gallien, et al. Corrosion Science 183 109319 (2021) https://doi.org/10.1016/j.corsci.2021.109319
Time-lapse synchrotron X-ray diffraction to monitor conservation coatings for heritage lead in atmospheres polluted with oak-emitted volatile organic compounds
Rosie Grayburn, Mark Dowsett, Michel De Keersmaecker, et al. Corrosion Science 82 280 (2014) https://doi.org/10.1016/j.corsci.2014.01.027
Corrosion resistance conferred by superhydrophobic fluorinated polyacrylate–silica composite coatings on cold‐rolled steel
Chang‐Jian Weng, Chih‐Wei Peng, Chi‐Hao Chang, Ya‐Han Chang and Jui‐Ming Yeh Journal of Applied Polymer Science 126 (S2) (2012) https://doi.org/10.1002/app.36380
Synergistic improvement of inhibitive activity of dicarboxylates in preventing mild steel corrosion in neutral aqueous solution
D Lahem, M Poelman, F Atmani and M-G Olivier Corrosion Engineering, Science and Technology 47 (6) 463 (2012) https://doi.org/10.1179/1743278212Y.0000000030
Corrosion inhibition of 2024 aluminium alloy by sodium decanoate
Grégory Boisier, Nicolas Portail and Nadine Pébère Electrochimica Acta 55 (21) 6182 (2010) https://doi.org/10.1016/j.electacta.2009.10.080
Corrosion protection of AA2024 sealed anodic layers using the hydrophobic properties of carboxylic acids
Grégory Boisier, Alain Lamure, Nadine Pébère, Nicolas Portail and Martine Villatte Surface and Coatings Technology 203 (22) 3420 (2009) https://doi.org/10.1016/j.surfcoat.2009.05.008
Potassium sorbate—A new aqueous copper corrosion inhibitor
Esta Abelev, David Starosvetsky and Yair Ein-Eli Electrochimica Acta 52 (5) 1975 (2007) https://doi.org/10.1016/j.electacta.2006.08.012
Inhibition treatment of the corrosion of lead artefacts in atmospheric conditions and by acetic acid vapour: use of sodium decanoate
E. Rocca, C. Rapin and F. Mirambet Corrosion Science 46 (3) 653 (2004) https://doi.org/10.1016/S0010-938X(03)00175-6
Inhibition of copper aqueous corrosion by non-toxic linear sodium heptanoate: mechanism and ECAFM study
E. Rocca, G. Bertrand, C. Rapin and J.C. Labrune Journal of Electroanalytical Chemistry 503 (1-2) 133 (2001) https://doi.org/10.1016/S0022-0728(01)00384-9
Effect of Linoleate on Electrochemical Behavior of Stainless Steel in Phosphate Buffer
S. Omanovic and S.G. Roscoe Corrosion 56 (7) 684 (2000) https://doi.org/10.5006/1.3280571
In-situ electrochemical atomic force microscopy studies of aqueous corrosion and inhibition of copper
G Bertrand, E Rocca, C Savall, et al. Journal of Electroanalytical Chemistry 489 (1-2) 38 (2000) https://doi.org/10.1016/S0022-0728(00)00163-7
In-situ ellipsometric study of copper passivation by copper heptanoate through electrochemical oxidation
N. Stein, L. Johann, C. Rapin and J.M. Lecuire Electrochimica Acta 43 (21-22) 3227 (1998) https://doi.org/10.1016/S0013-4686(98)00053-X