Issue |
Rev. Metall.
Volume 107, Number 2-3, February 2010
Fatigue damage, measurements and monitoring (Part 2)
|
|
---|---|---|
Page(s) | 51 - 57 | |
DOI | https://doi.org/10.1051/metal/2010006 | |
Published online | 11 May 2010 |
Étude de l’endommagement d’un acier inoxydable austénitique par fatigue multiaxiale à grand nombre de cycles*
Damage study of an austenitic stainless steel in high cycle multiaxial fatigue regime
1
CEA Saclay, DEN,
SRMA, 91191
Gif-sur-Yvette Cedex,
France
2
LMT Cachan (ENS Cachan/CNRS/UPMC/PRES UniverSud Paris) 61 av. du Président
Wilson, 94230
Cachan, France
3
EDF R&D / LaMSID, 1 avenue du Général de Gaulle, 92414
Clamart Cedex,
France
Reçu :
20
Janvier
2010
Dans le cadre de l’étude de la fatigue thermique de tuyauteries du parc de centrales nucléaires, des essais de fatigue multiaxiale à grand nombre de cycles sont effectués pour tenter de quantifier l’effet de la multiaxialité et de contrainte moyenne sur la durée de vie du matériau et alimenter un modèle d’endommagement à deux échelles. Des outils de mesures de champs cinématiques ainsi que d’observations micrographiques sont mis en place afin de tirer le maximum d’information de chaque essai : comportement cyclique, déformation plastique progressive, scénario d’apparition des fissures. Des résultats d’essais proportionnels et non-proportionnels sont présentés.
Abstract
Biaxial fatigue tests are performed up to 1 000 000 cycles at room temperature. Cross specimens of 304L steel thinned in their centre to initiate crack, are loaded by a biaxial testing machine. The strain at the centre of the sample is measured during loading using a stroboscopic Digital Image Correlation (DIC) technique, and crack initiation on the whole gauge zone is early detected by a second DIC-based measurement. A special optical assembly is designed to allow for simultaneous mesurements. Three types of loadings are performed: equibiaxial with a loading ratio R = 0.1, equibiaxial with loading ratio R = –1, pseudo uniaxial (cyclic loading at R = 0.1 in one direction and constant loading in the other). First results are commented.