Open Access

This article has an erratum: [https://doi.org/10.1051/metal/2024031]


Table 4

Parameters used on simulations at case study 1–Base case, Improved and Next generation scenario.

PARAMETERS BASE CASE IMPROVED SCENARIO NEXT GENERATION
AGGLOMERATION TECHNOLOGY Disks Disks Disks
QUANTITY OF AGGLOMERATION UNITS 10 10 10
PRODUCTION BY AGGLOMERATION UNIT 150 tph 150 tph 150 tph
ROLLER SCREEN CONFIGURATION      
• Quantity of rollers on top deck 20
• Gap opening on top deck (mm) 11
• Quantity of rollers to remove fines 45 45 45
• Gap opening to remove fines (mm) 8 7.8 7.7
• Quantity of rollers to remove oversized 15 15 15
• Gap opening to remove oversized (mm) 16 16 15.8
• Rollers length (mm) 1800 1800 1800
• Rollers diameter (mm) 75 75 75
• Rollers rotation speed (rpm) 120 120 120
• Screen inclination angle (C) 13 13 13
ROLLER FEEDER CONFIGURATION      
• Quantity of rollers to remove oversized (top deck) 20 20
• Gap opening to remove oversized (mm) 16 16
• Quantity of rollers in the middle deck 43 43
• Gap opening in the middle deck (mm) 10.5 10.5
• Quantity of rollers to remove fines (lower deck) 40 40 40
• Gap opening to remove fines (mm) 8 8 8
• Rollers length (mm) 4000 4000 4000
• Rollers diameter (mm) 89 89 89
• Rollers rotation speed (rpm) 100 100 100
• Screen inclination angle in the middle and lower decks (C) 21 21 21