Issue |
Rev. Met. Paris
Volume 94, Number 10, Octobre 1997
|
|
---|---|---|
Page(s) | 1195 - 1202 | |
DOI | https://doi.org/10.1051/metal/199794101195 | |
Published online | 17 January 2017 |
Temperature control from converter to tundish at BOS No. 2 of Hoogovens*
Contrôle de la température à l’aciérie 2 d’Hoogovens IJmuiden depuis le convertisseur jusqu’au répartiteur
The temperature losses of liquid steel after the last measured temperature in the converter are investigated. This investigation includes also the losses during ladle treatment. The results are described with relationships, based on theoretical considerations. The remaining error is close to the error of the measurement equipment. The developed model comes in operation during 1997 to improve the tundish temperature prediction (standard deviation : 3.5 °C).
© La Revue de Métallurgie 1997
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.